{"id":64,"date":"2020-05-11T16:37:50","date_gmt":"2020-05-11T23:37:50","guid":{"rendered":"https:\/\/www.irlabs.com\/?page_id=64"},"modified":"2023-08-27T12:26:20","modified_gmt":"2023-08-27T19:26:20","slug":"bolometers","status":"publish","type":"page","link":"https:\/\/www.irlabs.com\/products\/bolometers\/","title":{"rendered":"Bolometers & IR Detectors"},"content":{"rendered":"
We have supplied cooled IR bolometers and IR detectors to leading scientific organizations since 1967. We offer a full range of composite, silicon, hot electron, and germanium bolometers and photodetectors used for FTIR spectroscopy, high magnetic field research, terahertz research, molecular beam physics, and IR astronomy.<\/p>\n<\/div>
Highly sensitive:<\/strong> Our proven experience in cryogenics, electronics and optics sets the benchmark in sensitivity<\/p>\n Cost effective<\/strong>: Standard bolometers reduce project costs<\/p>\n Cryogen-free options:<\/strong> Eliminates needs for scarce and expensive liquid helium<\/p>\n Wide spectral range:<\/strong> Complete coverage of the IR spectral range<\/p>\n Customized configurations: <\/strong>Can be configured to meet specific application requirements including increased work height, dual detectors, filter positions and coupling optics<\/p>\n<\/div><\/div><\/div><\/div><\/div> Spectral Response (<\/b>\u00b5m)<\/b><\/p>\n<\/th>\n Cryogen-free Cooling<\/b><\/p>\n<\/th>\n<\/tr>\n<\/thead>\n\n 15 – 2000<\/p>\n<\/td>\n 15 – 500<\/p>\n<\/td>\n 15 – 2000<\/p>\n<\/td>\n 300 – 5000<\/p>\n<\/td>\n InSb Hot e-Bolometer<\/p>\n<\/td>\n 0.3mm – 5mm<\/p>\n<\/td>\nBolometer & IR Detector Comparison<\/h2>\n<\/div>\n
\n\n
\n \u00a0<\/b>Bolometers<\/b><\/th>\n \n Operating Temp
(K)<\/b><\/th>\nElectrical Sensitivity (S[V\/W])<\/b><\/th>\n Noise Equivalent Power
<\/b>[W\/Hz(1\/2)]<\/strong><\/th>\nNoise
<\/b>Vn[nV\/Hz(1\/2)]<\/strong><\/th>\nFrequency Response<\/strong>
(Optimum Chopping Frequency)<\/span><\/th>\nLiquid Cryogen Cooling<\/b><\/th>\n \n \n General Purpose 4.2 K Bolometer System<\/td>\n \n operation to 4.2<\/td>\n ~ 2.4 X 105<\/sup><\/td>\n ~ 2.5 X 10-13<\/sup><\/td>\n \u2264 80 at 80Hz<\/td>\n < 500 Hz<\/td>\n \u00a0<\/i><\/td>\n \u00a0<\/i><\/td>\n<\/tr>\n \n Hi Res 4.2K Bolometer System<\/td>\n \n operation to 4.2<\/td>\n ~ 6.1 X 105<\/sup><\/td>\n ~ 6.5 X 10-14<\/sup><\/td>\n \u2264 40 at 80Hz<\/td>\n < 200 Hz<\/td>\n \u00a0<\/i><\/td>\n \u00a0<\/i><\/td>\n<\/tr>\n \n Standard 1.6 K Bolometer System<\/td>\n \n 1.6<\/td>\n ~ 7.5 X 105<\/sup><\/td>\n ~ 4.6 X 10-14<\/sup><\/td>\n \u2264 40 at 80Hz<\/td>\n > 1 KHz<\/td>\n \u00a0<\/i><\/td>\n \u00a0<\/td>\n<\/tr>\n \n Far-IR 1.6 K Bolometer System<\/td>\n \n 1.6<\/td>\n ~ 1.0 X 107<\/sup><\/td>\n ~ 2.0 X 10-14<\/sup><\/td>\n \u2264 50 at 80Hz<\/td>\n < 300 Hz<\/td>\n \u00a0<\/i><\/td>\n \u00a0<\/td>\n<\/tr>\n \n \n \n 4.2<\/td>\n > 4.0 X 103<\/sup><\/td>\n \u00a0< 8 x 10-13<\/sup><\/td>\n < 4.0 at 200Hz<\/td>\n < 600 kHz<\/td>\n \u00a0<\/i><\/td>\n \u00a0<\/i><\/td>\n<\/tr>\n \n Photoconductors<\/strong><\/td>\n \u00a0<\/td>\n \u00a0<\/td>\n \u00a0<\/td>\n \u00a0<\/td>\n \u00a0<\/td>\n \u00a0<\/td>\n \u00a0<\/td>\n \u00a0<\/td>\n<\/tr>\n \n Si:B Photoconductor<\/td>\n 5 – 30<\/td>\n 4.2<\/td>\n SNR > 2.5 X 105<\/sup><\/td>\n < 5.0 X 10-12<\/sup><\/span><\/td>\n < 20\u00b5V\/Hz(1\/2)<\/sup> at 1kHz<\/span><\/td>\n DC to 5kHz<\/span><\/td>\n \u00a0<\/i><\/td>\n \u00a0<\/i><\/td>\n<\/tr>\n \n Ge:Ga Photoconductor<\/td>\n 40-120<\/td>\n 4.2<\/td>\n SNR > 2.5 X 105<\/sup><\/td>\n < 5.0 X 10-11<\/sup><\/span><\/td>\n < 10\u00b5V\/Hz(1\/2)<\/sup> at 1kHz<\/span><\/td>\n DC to 5kHz<\/td>\n \u00a0<\/i><\/td>\n \u00a0<\/i><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n